Spectrophotometer 45° / 0° with software

BGD 557
In stock

We will send you a price quotation with the correct prices as soon as possible, so you can confirm these.

Spectrophotometer 45° / 0° with software

Product Description

The BGD 557 Spectrophotometer uses combined LED precision spectroscopy to separate light at defined wavelength intervals. Sensor arrays provide sensitive spectral analysis, enabling accurate measurement of L*a*b* values and ΔE values. The instrument also displays spectral reflectance curves to support color matching and the calculation of color formulation parameters.

The BGD 557 Spectrophotometer is suitable for use in the plastics, electronics, paint, ink, textile, garment, printing and dyeing, food, medical, and cosmetics industries, as well as in research institutes, schools, and laboratories

The instrument measures spectral reflectance and other color indices, supporting color matching, color management, and product quality control. It comes with advanced color management software for PC connectivity and additional functionality

 


Technical Specification

  • Attractive, ergonomic design
  • 45°/0° optical geometry, compliant with CIE, ISO, ASTM, and DIN standards
  • Large 3.5-inch capacitive touchscreen
  • Two standard observer settings, multiple illuminant options, and a range of color systems
  • Repeatability of ΔE*ab ≤ 0.04
  • Inter-instrument agreement of ΔE*ab < 0.2
  • Storage capacity for more than 10,000 measurement records
  • PC software with extensive additional functionality
  • Advanced hardware incorporating multiple innovative technologies
  • Oversized integrating sphere for more uniform light distribution and precise measurement

 

 


Main Technical Parameters

 

More Information
Technical Parameters / Ordering Information BGD 557
Spectrophotometer
BGD 558/1
Spectrophotometer
BGD 558/3
Spectrophotometer
Illumination / Observation System 45/0 method (45° ring-shaped illumination, vertical viewing).
Complies with CIE No. 15
d/8° (diffused illumination, 8° viewing angle).
SCI / SCE measurement (including and excluding specular reflection)
UV included / UV excluded measurement.
Conforms to CIE No. 15, ISO 7724-1, ASTM E1164 and DIN 5033
Integrating Sphere Size Ø58 mm Ø48 mm
Light Source Combined LED source; UV light source available only for BGD 558/3.
Spectroscopic Mode — Concave grating
Sensor Silicon photodiode array 256-pixel dual-array CMOS image sensor
Wavelength Range 400–700 nm
Wavelength Interval 10 nm
Reflectance Range 0–200%
Illuminating / Measuring Aperture Single aperture:
MAV (large aperture): Ø8 mm / Ø10 mm
Single aperture:
MAV (large aperture): Ø8 mm / Ø10 mm
Dual apertures:
MAV (large aperture): Ø8 mm / Ø10 mm
SAV (small aperture): Ø4 mm / Ø5 mm
Measurement Mode SCE SCI & SCE
Color Space CIE LAB, XYZ, Yxy, LCh, CIE LUV, Hunter LAB (Hunter LAB only for BGD 558).
Color Difference Formula ΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc(2:1), ΔE*cmc(1:1), ΔE*00, ΔE (Hunter; only for BGD 558)
Other Chromaticity Data WI: ASTM E313, CIE/ISO, AATCC, Hunter.
YI: ASTM D1925, ASTM 313
TI: ASTM E313, CIE/ISO (only for BGD 558).
Metamerism Index MI; Color Stain; Color Fastness
Observer 2° / 10°
Illumination D65, A, C, D50, D55, D75, F1, F2 (CWF), F3, F4, F5, F6, F7 (DLF), F8, F9, F10 (TPL 5), F11 (TL 84), F12 (TL 83/U30)
Display Contents Spectral value / graph, colorimetric value, color difference value / graph, PASS/FAIL result, color offset, color simulation (color simulation only for BGD 557)
Measurement Time 1.5 s Approx. 1.2 s; approx. 3 s when measuring SCI and SCE simultaneously
Repeatability Spectral reflectance: MAV/SCI, standard deviation within 0.1% (400–700 nm: within 0.2%)
Colorimetric value: standard deviation within ΔE*ab 0.04
White calibration plate measured 30 times at 5-second intervals after white calibration
Spectral reflectance: MAV/SCI, standard deviation within 0.1% (400–700 nm: within 0.2%)
Colorimetric value: MAV/SCI, within ΔE*ab 0.04
Average value of the white calibration plate measured 30 times at 5-second intervals after calibration
Spectral reflectance: MAV/SCI, standard deviation within 0.08% (400–700 nm: within 0.18%)
Colorimetric value: MAV/SCI, within ΔE*ab 0.03
Average value of the white calibration plate measured 30 times at 5-second intervals after calibration
Inter-Instrument Agreement MAV/SCI, within ΔE*ab 0.2
Average value of 12 BCRA II series color tiles
MAV/SCI, within ΔE*ab 0.2
Average value of 12 BCRA II series color tiles
MAV/SCI, within ΔE*ab 0.15
Average value of 12 BCRA II series color tiles
Measurement Options Single measurement; average measurement (2–99 measurements).
Locating Mode — Camera view locating system
Dimensions (L × W × H) 90 × 77 × 230 mm 184 × 77 × 105 mm
Weight Approx. 600 g
Battery / Power Supply Li-ion battery; 5,000 measurements within 8 hours 4 AA alkaline batteries or power via USB interface
Lamp Life 5 years; more than 3 million measurements
Display Screen 3.5-inch TFT true-color capacitive touchscreen
Interface USB / RS-232; Bluetooth 4.0 Dual Mode (only for BGD 558/3; compatible with Bluetooth 2.1)
Data Memory 1,000 standards; 15,000 samples 1,000 standards; 20,000 samples.
Each record can include both SCI and SCE data
1,000 standards; 28,000 samples.
Each record can include both SCI and SCE data
Operating Conditions 0–40 °C; 0–85% RH, non-condensing
Elevation: below 2,000 m
Storage Conditions −20 to +50 °C; 0–85% RH, non-condensing
Standard Accessories Power adapter and Li-ion battery (BGD 557) or 4 AA alkaline batteries (BGD 558); data cable; operating instructions; CD-ROM containing management software; white and black calibration cavity; protective cover
Optional Accessories BGD 1390 — Special test box for powder
BGD 1393 — Mini printer
BGD 1395 — Universal test components