Xenon Test Chamber: 6.5 kW; PLC auto-control
BGD 862
We will send you a price quotation with the correct prices as soon as possible, so you can confirm these.
BGD 862 Xenon Test Chamber: 6.5kW; PLC auto-control, water-cooled long-arc xenon lamp
Ordering Information → Technical Item ↓ |
BGD 862 Xenon Test Chamber |
Xenon Lamp |
6.5 kiW water cooling long arc xenon lamp |
Light Filter |
Import originally from ATLAS, can simulate indoor or outdoor sunshine spectrum |
Exposure Area |
6,500 cm2 |
Wave Length of Xenon Spectrum |
Can select 300-800nm(simulate sunshine,filtrate all wavelength under 300nm)or 280-800nm (Add UV wave,keep some short-wave of UV) |
Adjustable Irradiance |
0.3~1.5 W/ m2 (Single point of control: 340nm) 30 W/m2~150 W/ m2 (Full spectrum :from 300~400nm) |
Lifetime of lamps |
2,000 hours |
Adjustable BPT |
RT+20℃~110℃ |
Temperature Stability |
±1℃ |
Temperature Uniformity |
≤2℃ |
Temperature Declination |
≤±1℃ |
Adjustable Humidity |
Light: 10%-85% Dark:10%-95% |
Rotate speed of sample |
1 r/min(circle as lamp centre) |
Spray Function |
Can set spray continuous time and spray period |
Water demands |
High purity deionized water(Conductivity <2us/cm) |
Flow of Deionized Water |
0.2L/min |
Overall Size |
1,200*1,200*2,000mm(L*W*H) |
Net Weight |
500 KG |
Optional Pure Water Machine |
Size:680*560*1600(L*W*H) |
Main Technical Parameters
Structure |
|
Cabinet Material |
Working room is made up of good quality stainless steel (SUS316) |
Chamber Door |
Simple door to left with filter window;silicon rubber seal the door edge |
Sample Crack |
Stainless steel material, its position in the chamber can be adjusted(up, middle or down), Sample crack rotate around the centre of lamp |
Controller |
Siemens programmable controller. LCD touch-screen |
Way of adding humidity |
Add humidity by ultrasonic humidifier |
Black panel thermometer |
Heat insulate type black standard thermometer |
Cooling System |
Cooled by compressor and forced-air blast system |
Security Protections And Error Protections |
|
Xenon Lamp Protection |
Protection to cooling water for xenon lamp shortage. Protection to big electric current to xenon lamp Protection to big irradiance deviation for a long time |
Water Shortage Protection |
Water shortage, cooling water to lamp shortage, low flow rate of cooling water, water shortage when heating |
Power Source Protection |
Over-power, over-electric current, shortage phase and wrong phase sequence |
Working Room Temperature Protect |
Individual over-temperature protection of working room temperature. Over-temperature protection for BPT and BST |
Pure System Protect |
Monitor the conductivity of pure water at real-tim(Once the conductivity≥2us/cm, the machine will stop and alarm) |
Protection to Radiation |
Xenon lamp will turn off automatically when opening the chamber door, in case xenon lamp radiate operator |
Installing & Environment Requirements |
|
Power Source |
380V±10% 3-phases 4 lines or 220V±10% 2-phase; 50 or 60Hz;Max. electric current ≥40A;Max. power: 8kW |
Air Outlet |
There should be air outlet in the installation place to connect vent pipe |
Standard Accessories |
|
Xenon Lamp: 1 pc (Either Atlas or Chinese brand) Sensor: 2 pcs (OSRAM) Xenon Lamp Filter: 1 set (Either Atlas or Chinese brand) Siemens Control System: 1 set Touch Screen Cmputer Interface: 1 pc Specimen Holders: 65 pcs Black Panel Temperature Holders: 2 pcs (include 2 units of PT 100) Irradiance Calibration Holder: 1 pc |